Lọc theo danh mục
  • Năm xuất bản
    Xem thêm
  • Lĩnh vực
liên kết website
Lượt truy cập
 Lượt truy cập :  22,778,205
  • Công bố khoa học và công nghệ Việt Nam

Khoa học y, dược

BB

Nguyễn Thị Kim Anh, Dương Thị Bích Chi, Lê Thị Thanh Trân(1)

XÁC NHẬN GIÁ TRỊ SỬ DỤNG CỦA PHƯƠNG PHÁP PHÂN TÍCH CÁC HỢP CHẤT BENZYL ALCOHOL TRONG MẪU NƯỚC KHAI THÁC DẦU BẰNG SẮC KÝ KHÍ KHỐI PHỔ

VALIDATION OF ANALYTICAL METHOD FOR BENZYL ALCOHOL COMPOUNDS IN OIL PRODUCTION WATER SAMPLES USING GAS CHROMATOGRAPHY-MASS SPECTROMETRY

Tạp chí Phân tích Hóa, Lý và Sinh học

2024

2

01

In this study, a procedure to simultaneously analyze three benzyl alcohol compounds including 2fluorobenzyl alcohol (2-FBOH), 2,6-dichorobenzyl alcohol (2,6-DClBOH) and 3,4-difluorobenzyl alcohol (3,4-DFBOH) in produced water samples was developed for the application in a partitioning inter-well tracer test to determine residual oil saturation (Sor) in oilfield production. The sample was passed through a solid phase extraction column, then the column was dried under vacuum and flushed with 5 mL of acetonitrile. The obtained acetonotrile extract was measured on a gas chromatography-mass spectrometrer (GC-MS). The analytical method met AOAC requirements for detectability, recovery and repeatability. Depending on each benzyl alcohol compound, the limit of detection (LOD) of the method was in the range of 7 - 10 µg/L, the limit of quantification ( LOQ) ranges from 24 to 32 µg /L, recovery was achieved from 90 to 110% and the relative deviation values of (RSD) was below 9%.

In this study, a procedure to simultaneously analyze three benzyl alcohol compounds including 2fluorobenzyl alcohol (2-FBOH), 2,6-dichorobenzyl alcohol (2,6-DClBOH) and 3,4-difluorobenzyl alcohol (3,4-DFBOH) in produced water samples was developed for the application in a partitioning inter-well tracer test to determine residual oil saturation (Sor) in oilfield production. The sample was passed through a solid phase extraction column, then the column was dried under vacuum and flushed with 5 mL of acetonitrile. The obtained acetonotrile extract was measured on a gas chromatography-mass spectrometrer (GC-MS). The analytical method met AOAC requirements for detectability, recovery and repeatability. Depending on each benzyl alcohol compound, the limit of detection (LOD) of the method was in the range of 7 - 10 µg/L, the limit of quantification ( LOQ) ranges from 24 to 32 µg /L, recovery was achieved from 90 to 110% and the relative deviation values of (RSD) was below 9%.